Skip to main content

Table 3 Performance characteristics of biomarkers to detect clinical response in SLE (reduction in ECLAM score of 3 or more)

From: Improved monitoring of clinical response in Systemic Lupus Erythematosus by longitudinal trend in soluble vascular cell adhesion molecule-1

 

Spearman correlation

Mixed-effects

ROC curve analysis

Biomarker

r value

P value

P value

AUC (95 % CI)

Youden index

Sensitivity (%)

Specificity (%)

PPV (%)

NPV (%)

∆sVCAM-1

0.622

9.7 × 10−10

3.9 × 10−9

0.899 (0.808 − 0.968)

0.703

86.4

83.9

67.9

94.0

∆sICAM-1

0.357

0.0012

3.4 × 10−5

0.688 (0.537 − 0.824)

0.426

72.7

69.9

48.5

86.7

∆sE-selectin

0.162

NS

1.0 × 10−4

0.569 (0.382 − 0.737)

0.338

40.9

92.9

69.2

80.0

∆sP-selectin

−0.092

NS

NS

0.541 (0.385 − 0.692)

0.287

59.1

69.6

43.3

81.2

∆ESR

0.211

0.062

8.3 × 10−5

0.586 (0.417 − 0.738)

0.302

40.9

89.3

60.0

79.4

∆dsDNA

0.292

0.0085

0.052

0.731 (0.581 − 0.860)

0.550

81.8

73.2

54.5

91.1

∆C3

−0.367

8.0 × 10−4

2.9 × 10−4

0.772 (0.634 − 0.890)

0.639

81.8

82.1

64.3

92.0

∆C4

−0.274

0.014

NS

0.689 (0.543− 0.821)

0.406

72.7

67.9

47.1

86.4

  1. AUC area under ROC curve, CI confidence interval, dsDNA double-stranded DNA, ECLAM European Consensus Lupus Activity Measure, ESR erythrocyte sedimentation rate, NPV negative predictive value, NS not significant, PPV positive predictive value, r Spearman correlation for each parameter against ∆ECLAM, ROC receiver operating characteristic, sE-selectin soluble E-selectin, sICAM-1 soluble intercellular adhesion molecule-1, SLE systemic lupus erythematosus, sP-selectin soluble P-selectin, sVCAM-1 soluble vascular cell adhesion molecule-1