Table 4 Mean values ± standard deviation and intergroup comparisons of flexor tendon pulley thickness in PsA, RA, and HC patients

From: High-resolution MRI of flexor tendon pulleys using a 16-channel hand coil: disease detection and differentiation of psoriatic and rheumatoid arthritis

Finger + pulley

PsA

RA

HC

PsA vs RA

PsA vs HC

RA vs HC

Pulley thickness in mm

p value

D2 A1

0.86 ± 0.14

0.63 ± 0.10

0.62 ± 0.16

< 0.001

< 0.001

0.99

D2 A2

0.79 ± 0.13

0.54 ± 0.09

0.6 ± 0.11

< 0.001

< 0.001

0.45

D3 A1

0.82 ± 0.19

0.6 ± 0.09

0.64 ± 0.11

< 0.001

0.002

0.76

D3 A2

0.83 ± 0.11

0.58 ± 0.12

0.66 ± 0.18

< 0.001

0.006

0.269

D4 A1

0.71 ± 0.16

0.6 ± 0.09

0.61 ± 0.09

0.03

0.09

0.94

D4 A2

0.79 ± 0.12

0.58 ± 0.12

0.63 ± 0.13

< 0.001

0.008

0.54

D5 A1

0.76 ± 0.21

0.58 ± 0.08

0.64 ± 0.13

0.005

0.1

0.56

D5 A2

0.71 ± 0.21

0.61 ± 0.08

0.61 ± 0.12

0.13

0.15

1

D2–5 A1

0.79 ± 0.18

0.6 ± 0.09

0.63 ± 0.13

< 0.001

< 0.001

0.74

D2–5 A2

0.78 ± 0.15

0.58 ± 0.22

0.63 ± 0.14

< 0.001

< 0.001

0.21

D2–5 A1 + 2

0.79 ± 0.17

0.59 ± 0.19

0.63 ± 0.13

< 0.001

< 0.001

0.35

  1. After (adapted) Bonferroni correction, p values < 0.0167 were considered significant and are printed in bold type