Table 6 Sub-analysis of patients who all received a pulmonary HRCT. Baseline characteristics and sensitivity, specificity, positive likelihood ratio (LR+), negative likelihood ratio (LR−), and area under the curve (AUC) for different diagnostic procedures in the detection of lung involvement in IRD patients with ILD

From: Assessing the diagnostic value of a potential screening tool for detecting early interstitial lung disease at the onset of inflammatory rheumatic diseases

Variable

ILD group, number (%)

Non-ILD group, number (%)

Difference

AUC

Number

38 (50.0%)

38 (50.0%)

  

Age

59.7 ± 15.0 years

53.2 ± 14.7 years

t(74) = 1.91,P = 0.060

 

PFT

37 (97.4%)

37 (97.4%)

χ2(1) = 0.000,P = 1.000

 

Median ± SD

 DLCO

57.8 ± 19.3%

76.0 ± 19.7%

t(71) = 3.99,P < 0.001

0.745 (0.633–0.857; P < 0.001)

DLCO < 80%: sensitivity = 86.5%, specificity = 36.1%, LR+ = 1.35, LR− = 0.37

 TLC

82.7 ± 20.8%

97.4 ± 12.9%

t(51.1) = 3.49,P = 0.001

0.724 (0.598–0.849; P = 0.002)

TLC < 80%: sensitivity = 39.4%, specificity = 94.1%, LR+ = 6.70, LR− = 0.64

 FVC

78.9 ± 22.2%

91.3 ± 16.4%

t(64.5) = 2.70,P = 0.009

0.667 (0.539–0.794; P = 0.014)

FVC < 80%: sensitivity = 55.6%, specificity = 78.5%, LR+ = 2.57, LR− = 0.57

 FEV1

80.5 ± 23.5%

91.1 ± 14.3%

t(55.5) = 2.30,P = 0.025

0.649 (0.517–0.782; P = 0.029)

FEV1 < 80%: sensitivity = 54.3%, specificity = 78.4%, LR+ = 2.51, LR− = 0.58

 TLCO

74.6 ± 18.5%

82.8 ± 17.4%

t(97) = 1.93,P = 0.058

0.615 (0.485–0.746; P = 0.095)

TLCO < 80%: sensitivity = 60.0%, specificity = 55.6%, LR+ = 1.35, LR− = 0.72

Chest X-ray

29 (76.3%)

29 (76.3%)

χ2(1) = 0.000,P = 1.000

 

Sensitivity = 72.4%, specificity = 58.6%, LR+ = 1.75, LR− = 0.47

HRCT

38 (100.0%)

38 (100.0%)

χ2(1) = 0.000,P = 1.000

 

Sensitivity = 100.0%, specificity = 52.6%, LR+ = 2.11, LR− = < 0.01

Combination of chest X-ray and/or

 DLCO < 80%

Sensitivity = 89.5%, specificity = 26.3%, LR+ = 1.21, LR− = 0.40

 DLCO < 70%

Sensitivity = 84.2%, specificity = 50.0%, LR+ = 1.68, LR− = 0.32

 FVC < 80%

Sensitivity = 78.9%, specificity = 57.9%, LR+ = 1.88, LR− = 0.36

 FVC < 70%

Sensitivity = 71.1%, specificity = 65.8%, LR+ = 2.08, LR− = 0.44

Combination of the following:

1. DLCO < 80% and/or chest X-ray and

2. HRCT

Sensitivity = 89.5%, specificity = 65.8%, LR+ = 2.62, LR− = 0.16

  1. DLCO Diffusing capacity for carbon monoxide, FEV1 Forced expiratory volume in 1 s, FVC Forced vital capacity, HRCT High-resolution computed tomography, LR Likelihood ratio, PFT Pulmonary function tests, TLC Total lung capacity, TLCO Transfer factor of the lung for carbon monoxide